Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.403
Filtrar
2.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599687

RESUMO

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Qualidade de Vida , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
4.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco/métodos
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38603618

RESUMO

OBJECTIVES: Recurrence of tricuspid regurgitation (TR) after tricuspid annuloplasty can occur in cases where a dilated right ventricle exists and subsequent leaflet tethering follows. We previously reported a new technique of the right ventricular papillary muscle approximation (RV-PMA) for functional TR associated with leaflet tethering. The objective of this study is to elucidate the mid-term outcomes and evaluate the durability of RV-PMA. METHODS: Between January 2014 and March 2023, we applied RV-PMA in 20 patients of advanced functional TR with severe leaflet tethering. The indication of the technique was severe TR with leaflet tethering height >8 mm, and/or a right ventricular end-diastolic diameter >45 mm. The patients were followed up with echocardiography before discharge and at annual interval thereafter. RESULTS: There was no perioperative mortality. In the echocardiography performed before discharge, TR was decreased to mild or less in 85%, and a significant improvement in right ventricular end-diastolic diameter and tethering height were achieved (53-45 mm and 11.1-4.4 mm, respectively). Furthermore, during the median 3-year follow-up period, TR was kept controlled mild or less in 80% of the cases. CONCLUSIONS: RV-PMA is considered to be a safe, effective and durable technique as an additional approach for tricuspid annuloplasty.


Assuntos
Ventrículos do Coração , Músculos Papilares , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Músculos Papilares/cirurgia , Músculos Papilares/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ventrículos do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Resultado do Tratamento , Ecocardiografia , Anuloplastia da Valva Cardíaca/métodos , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Índice de Gravidade de Doença , Seguimentos
9.
J Cardiothorac Surg ; 19(1): 193, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594763

RESUMO

In this case report, we present the unique and intriguing case of a 57-year-old man who experienced exertional palpitations and shortness of breath for 5 years. He was diagnosed with idiopathic heart failure three years ago, leading to diuretic treatment. Physical examination revealed notable left lower extremity swelling, severe varicose veins, and cardiac murmurs. Echocardiography showed significant cardiac enlargement and severe functional mitral and tricuspid valve regurgitation. Computed tomography (CT) imaging uncovered a 10 mm left common iliac arteriovenous fistula, causing abnormal early filling of the inferior vena cava (IVC) and marked IVC dilation. Open surgical repair of the arteriovenous fistula resulted in symptom relief and improved cardiac function. This case underscores the importance of considering unusual causes in heart failure patients and highlights the value of early diagnosis and intervention in complex cardiac-vascular interactions.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Ecocardiografia , Insuficiência da Valva Tricúspide/cirurgia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/etiologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
11.
JACC Cardiovasc Interv ; 17(8): 1073-1075, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658125
12.
J Int Med Res ; 52(3): 3000605241233524, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38497134

RESUMO

OBJECTIVE: To develop an experimental porcine model of tricuspid regurgitation using two induction routes: the inferior vena cava and superior vena cava. METHODS: Tricuspid regurgitation was generated using the loop wire cutting method. The tricuspid regurgitation jet direction was controlled by accessing the valve through the inferior (n = 7) or superior (n = 6) vena cava. The occurrence, direction, and progression of tricuspid regurgitation were assessed postoperatively, and echocardiography was performed at 4 to 6 weeks. Right heart dilatation was assessed using computed tomography after 6 weeks. RESULTS: Moderate to severe or torrential tricuspid regurgitation occurred immediately after the procedure in 12 of 13 animals. The jet was directed toward the septum in five of seven animals in the inferior vena cava group and toward the posterolateral side in four of six animals in the superior vena cava group. The dimensions of the right heart (right atrium, ventricle, and tricuspid valve annulus) were significantly enlarged at the 4- to 6-week follow-up echocardiographic examination and confirmed to be enlarged by computed tomography, independent of the route used. CONCLUSION: The loop wire cutting method successfully induced a disease model of tricuspid regurgitation while controlling the regurgitation jet direction via two procedural routes.


Assuntos
Insuficiência da Valva Tricúspide , Suínos , Animais , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Superior , Átrios do Coração/diagnóstico por imagem , Ecocardiografia , Cardiomegalia
14.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
15.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
17.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450808

RESUMO

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca
18.
J Am Heart Assoc ; 13(6): e032999, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471826

RESUMO

Tricuspid regurgitation is a common yet clinically complex problem, traditionally managed with diuretic therapy with no observable mortality benefit. Older studies on surgical intervention observed poor outcomes; however, this clinical reasoning predates current surgical approaches and novel transcatheter technology. The tricuspid apparatus is a complex structure that poses a technical challenge for surgeons and interventional cardiologists. Recent advances in surgical techniques and transcatheter therapy, particularly edge-to-edge repair devices, have demonstrated promising results for safety, reduction in tricuspid regurgitation, and improving quality of life. We review the clinical, imaging, and hemodynamic findings that characterize patients who should be considered for intervention, alongside the rapidly evolving approaches to interventional management.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos
20.
Sci Rep ; 14(1): 5120, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429438

RESUMO

There is a great demand for development of a functional tricuspid regurgitation (FTR) model for accelerating development and preclinical study of tricuspid interventional repair devices. This study aimed to develop a severe FTR model by creating a tissue-silicone integrated right ventricular pulsatile circulatory simulator. The simulator incorporates the porcine tricuspid annulus, valve leaflets, chordae tendineae, papillary muscles, and right ventricular wall as one continuous piece of tissue, thereby preserving essential anatomical relationships of the tricuspid valve (TV) complex. We dilated the TV annulus with collagenolytic enzymes under applying stepwise dilation, and successfully achieved a severe FTR model with a regurgitant volume of 45 ± 9 mL/beat and a flow jet area of 15.8 ± 2.3 cm2 (n = 6). Compared to a normal model, the severe FTR model exhibited a larger annular circumference (133.1 ± 8.2 mm vs. 115.7 ± 5.5 mm; p = 0.009) and lower coaptation height (6.6 ± 1.0 mm vs. 17.7 ± 1.3 mm; p = 0.003). Following the De-Vega annular augmentation procedure to the severe FTR model, a significant reduction in regurgitant volume and flow jet area were observed. This severe FTR model may open new avenues for the development and evaluation of transcatheter TV devices.


Assuntos
Insuficiência da Valva Tricúspide , Suínos , Animais , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide , Ventrículos do Coração , Cordas Tendinosas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...